Vacuum Test Gauge Instructions
Dometic Corporation
13128 State Rt 226
Big Prairie, OH 44611
1-800-321-9886
TO IDENTIFY VACUUM LEAK LOCATION IN VACUUM TANK/VACUUM PUMP SYSTEM
Before starting vacuum tests, determine the amount of time between pump cycles or the amount of
vacuum drop within a specific time span.
PART 1
1. Remove vacuum hose from inlet on vacuum tank (fig. D).
2. Insert rubber plug in tank inlet.
3. Note vacuum reading, then determine time between pump cycles.
If time between pump cycles increases or no vacuum drop is recorded on test gauge, the
leak is before the vacuum tank. Go to Part 2.
If time between pump cycles remains the same or a vacuum drop is recorded on test gauge,
go to Part 4.
PART 2
1. Reinstall vacuum hose on vacuum tank inlet.
2. Remove hose from toilet outlet (fig. C).
3. Insert rubber plug into open end of hose.
If time between pump cycles increases or no vacuum drop is recorded on test gauge, go to
Part 3.
If time between pump cycles remains the same or a vacuum drop is recorded on test gauge,
the leak is in the hose between the toilet and vacuum tank. Retighten connections or replace
hose as necessary.
TO DETERMINE SYSTEM VACUUM LEAK RATE AND TIME BETWEEN PUMP CYCLING
1. Turn off water to toilet.
2. Open the toilet’s flush ball and insert the rubber plug into the 1" orifice in the bottom of the
base. The vacuum pump will be running.
3. After the vacuum pump shuts off, allow the gauge to stabilize for a minute.
4. Record the vacuum reading to the nearest two-tenths of an inch. (.2")
5. Keeping the rubber plug in the 1" orifice, wait 30 minutes, and then record a second reading.
6. Subtract the two readings and record the drop in vacuum.
TO IDENTIFY VACUUM LEAK LOCATION IN VACUUM GENERATOR SYSTEM
1. Turn off water to toilet.
2. Open the toilet flush ball and insert rubber plug into 1" orifice in the bottom of the base
(fig. A). If there is no vacuum leak at this point, the leak is above the 1" orifice in the base:
Check for a crack in the base, funnel, or flush ball.
If there is a vacuum leak, go to next step.
3. Remove inlet hose to vacuum generator and insert rubber plug in the inlet fitting (fig. B).
If there is no vacuum leak at this point, the leak is between the toilet and the vacuum generator:
Check the hose and clamps between the toilet and the vacuum generator.
If there is a vacuum leak:
Check duckbill valves for foreign objects or cuts.
Check spin nut and fitting between pump and vacuum tank.
Drop in Vacuum (30 min.)
Time Between Pump Cycles
.4" Hg (not acceptable)
.3" Hg* (acceptable)
.2" Hg (good)
2.5 hours
3.3 hours
5.0 hours
* Maximum acceptable leak rate.
B
VACUUM
GENERATOR
VACUUM
TOILET
REMOVE
INLET
HOSE
PART 3
1. Reinstall vacuum hose on toilet outlet.
2. Turn off incoming water and prop open flush valve in toilet.
3. Insert rubber plug into 1" orifice in the bottom of the base (fig. A).
If time between pump cycles increases or no vacuum drop is recorded on test gauge,
the vacuum leak is in the toilet seals or rotor shaft.
If time between pump cycles remains the same or a vacuum drop is recorded on test
gauge, the leak is in the toilet outlet fittings or funnel. Replace funnel, or repair/replace
fittings as necessary.
PART 4
1. Reinstall vacuum hose to vacuum tank inlet.
2. Shut off power to vacuum pump.
3. Remove hose from vacuum tank outlet (fig. E).
4. Insert rubber plug into vacuum hose.
5. Turn on power to vacuum pump.
6. Shut off vacuum pump at about 10 in. Hg on test gauge.
If no vacuum drop is recorded, the leak is in the vacuum tank.
Tighten or reinstall fittings as necessary.
If a vacuum drop is recorded, go to Part 5.
PART 5
1. Reinstall vacuum hose to vacuum tank outlet.
2. Remove hose from inlet on vacuum pump (fig. F).
3. Insert rubber plug into inlet of pump.
4. Turn on power to vacuum pump.
5. Shut off vacuum pump at about 10 in. Hg on test gauge.
If a vacuum drop is recorded, inspect the valves and fittings in the pump.
Tighten or replace as necessary.
If no vacuum drop is recorded, inspect hose between vacuum tank and pump.
Tighten or replace as necessary.
A
600342275 10/05
VACUUM
TANK
VACUUM
PUMP
VACUUM TOILET
C
F
E
D
Page view 0
1 2

Summary of Contents

Page 1 - (fig. D)

Vacuum Test Gauge InstructionsDometic Corporation13128 State Rt 226Big Prairie, OH 446111-800-321-9886TO IDENTIFY VACUUM LEAK LOCATION IN VACUUM TANK/

Page 2 - Water Supply Line

Water Valve Installation InstructionsVacuum/Discharge Pump Repair Kit InstructionsPUMP BODYLarge rubber sealPlastic bushingRubberO-ringSeaLand Duckbil

Comments to this Manuals

No comments